-40%
Mersen A2D-R Amp-Trap 2000 Time-Delay/Class RK1 Fuse with Visual Open Fuse In...
$ 49.62
- Description
- Size Guide
Description
Mersen A2D-R Amp-Trap 2000 Time-Delay/Class RK1 Fuse with Visual Open Fuse Indicator, 250VAC/DC, 200kA AC/100kA DC, 600 Ampere, 2-9/16" Diameter x 10-3/8" LengthProduct Description Mersen Amp-Trap 2000 SmartSpot A2D-R fuses feature a visual open fuse indicator and provide IEC Type 2 No Damage protection to main, feeder, and branch circuits for all types of loads. With time-delay characteristics for handling harmless in-rush currents, current-limiting ability, A2D-R fuses give excellent protection for all your applications. Solid state SmartSpot visual blown fuse indicator. 600VAC and 600VDC dual rated Easy 2-to-1 selectivity for prevention of nuisance shut downs and "black outs" Rejection-style design prevents replacement errors (when used with recommended fuse blocks) High-visibility orange label gives instant brand recognition Reduced inventory by taking the place of class RK5, K, and H fuses Metal-embossed date and catalog number for easier traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings Applications: Motors, safety switches, transformers, branch circuit protection, disconnects, control panels, and all general-purpose circuits. 600 ampere current rating.Measure 2-9/16-inches diameter by 10-3/8-inches length. Approvals: UL listed to standard 248-12 file E2137, DC listed to UL standard 248, CSA certified to standard C22.2 No. 248.12. From the Manufacturer Mersen A2D600R 250V 600A Rk1 Time Delay Fuse, UL Power Fuse, Class Rk1, Time Delay Characteristics, 250 Vac, 600 Ampere, Interrupting Rating 200 Kiloampere, Blade Terminal, Diameter 2-9/16 Inch, Length 10-3/8 Inch, Approval Ul 248-12, Csa C22.2, Amp-Trap 2000[R] Brand, A2D Model, Current Limiting, Fiberglass Tube
Time-delay/class RK1 fuses with visual open fuse indicator
Time-delay for motor starting and transformer inrush currents without nuisance opening
300kA interrupting rating - self-certified, UL witnessed tests
Extremely current-limiting for low peak let-thru current
Recommended for Arc flash energy reduction
Class Rk1
Time Delay Characteristics
250 Vac
600 Ampere
Interrupting Rating 200 Kiloampere